Call our Helpline:
Antipodes Power logo

Smart Power. Smart City.

APS SOLAR SPD PV 2P– CLASS II 48VDC

Key Features:

  • EN50539, IEC61643-11, and UL1449-4th Edition 
  • Common mode protection with DC SPD 
  • Modules that can be plugged in and replaced easily 
  • 40kA discharge current 8/20 
  • For disconnected devices, reliable supervision is provided. 
  • The red indicator flag in the window indicates a fault. 
  • Features a remote alarm terminal output 
Category

Description

Surge arresters of Type 2 are designed to protect low-voltage DC systems from surges at the boundaries of lightning protection zones 0B-2 and higher. The APS Surge protection device is Class II approved. It protects PV photovoltaic panels against lightning by providing overvoltage protection. The device is connected in series with the DC cables of the solar panel strings. Surge Arrestors protect solar panels and inverters from lightning strikes, and the PST31PV from APS includes a high-energy MOV, thermal fuse, and thermal disconnection mechanism. There is also a remote-control signal option. 

Specifications

APS SPD PV 2P– CLASS II 48VDC

Part. No PV40-48-V-C-S
In accordance with EN 50539;IEC 61643 - 11:2011; UL1449-4th
Category IEC / VDE II/ C
Protection Mode Common Mode
Nominal Voltage (VDC) Un 48
Max. Continuous Operating Voltage (VDC) Uc 75
Nominal Discharge Current (8/20) In 20kA
Nominal Discharge Current (8/20) Imax 40kA
Nominal Discharge Current (8/20) Up <350V
VPR <300V
Response Time ≤25 ns
Follow Current No
Backup Fuse (only if not provided by mains) 125A gR / gPV
Operating Temperature Range - 40 °C ~ + 80 °C
Cross-section of Connection Wire Single-strand 35mm2 ; multi-strand 25mm2
Mounting 35mm DIN-rail in accordance with EN 50022 / DIN46277-3
Enclosure Material Thermoplastic; extinguishing degree UL94 V-0
Degree of Protection IP20
Installation Width 2 modules, DIN 43880
Thermal Disconnector Internal green – normal; red – failure
Remote Alarm Contact Optional
Approvals, Certifications CE
Additional Data for Remote Alarm Contacts
Remote Alarm Contact Type Isolated Form C
Switching Capability Un / In AC: 250V/0.5A
DC: 250V/0.1A; 125V/0.2A; 75V/0.5A
Max. Size of Connecting Wire Max. 1.5mm2 (or # 16AWG)

Product PDF

Download the Product Brochure By Clicking the Link Below

APS-SPD PV 2P Class II 48 VDC

1 review for APS SOLAR SPD PV 2P– CLASS II 48VDC

  1. Lachlan

    With this easy to use SPD I can be at peace knowing my devices are safe and secure. I love it!

Add a review

Your email address will not be published. Required fields are marked *

Make your Enquiry.